Spirometer Kit Portable Orbit™ +/- 14 L/s PC Display Disposable Mouthpiece
Sold by: EA OF 1

 Reviews
Better together

  • Total: $0.00

Rally #131-1-0101
Vectracor QRS Diagnostics #Z-7000-0101
Orbit™ Spirometer (1/EA)

Spirometer, Orbit, Portable, USB connection, office medic and accessories included, Flow ±14 liters/second, Volume 0.5 – 8 liters, Pre-Calibrated Mouthpiece.

[Combo Package Bundle Available: 790009-01 - ECG & Spirometer Combo, PC Based, Office Medic Software Included]

Orbit™ Spirometer Features
  • Connects directly to PC, laptop, or tablet.
  • Eliminates calibration and sterilization with disposable nose-clips and pre-calibrated mouthpieces.
  • Integrates with Office Medic™ software and EMR system.
  • Provides patient safety by reducing cross-contamination liability.
  • No batteries required as power is drawn from the PC.
  • Allows unlimited data storage with PC and EMR connectivity.
  • Combines with Office Medic™ software for customizable reports and transfer of files.
Office Medic Features
  • Instantly stores the test data in its central database allowing you to manage & review it from anywhere.
  • Create customizable reports in PDF, JPEG, and TIFF formats to integrate with your EMR.
  • Multiple Language Options: English, French, German, Italian, Portuguese, and Spanish.
  • Up to 5 years of Warranty
The Orbit™ is a portable spirometer that connects to PCs, laptops, and tablets. It simplifies testing by using disposable, pre-calibrated mouthpieces and nose clipss, eliminating calibration and sterilization needs. The device requires no batteries, as it draws power from the PC and can integrates with Office Medic™ software for easy data storage and customizable report generation.

Office Medic is user-friendly software that comes with all VectraCor QRS ECGs and Spirometers. It allows users to collect, store, and review diagnostic data using a regular laptop, desktop, or tablet. The software saves test data in a central database, enabling access from anywhere and creating customizable reports in PDF, JPEG, and TIFF formats to integrate with EMR systems.

Note
  • Rx Only - Federal law restricts this device to the sale by or on the order of a physician.
  • This item is non-returnable and non-refundable. Please make sure it is the right product and quantity before you order.
For the State of California:
Warning: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.

×
Rally #131-1-0101
Manufacturer #Z-7000-0101
BrandOrbit™
ManufacturerQRS Diagnostic
Country of OriginUnited States
ApplicationSpirometer Kit
Flow Rate+/- 14 L/s
Communication PortUSB
IndicatorWithout Indicator
UNSPSC Code42271602
UsageDisposable Mouthpiece
Warranty3 Years



Orbit Spirometer
Weight226.8 grams (0.5 lb.)
Dimensions109.2 mm x 94.0 mm x 43.2 mm (4.3” x 3.7” x 1.7”)
Communication PortUSB
Software CompatibilityOffice Medic Version 5.5 (or later)
Power Supply5 Vdc ±5% 100 mA or less from the host PC USB Port
Spirometry Measurement PrincipleThe pressure is converted to flow.
Volume measurement by flow integration.
Measurement TimeFVC: 60 sec.
SVC: 60 sec.
MVV: 15 sec.
Sampling Rate125 Hz
Range (BTPS)Flow: ±14 liters/second
Volume: 0.5 – 8.0 liters
Accuracy (BTPS) Flow:
  • FEF 25-75: ±5% of indication or ±200 ml/sec, whichever is greater
  • PEF: ±10% of indication or ±300 ml/sec, whichever is greater
Volume: ±3% of indication or ±50 ml, whichever is greater for FVC and FEV1
  • FVC and FEV1: ±3% of indication or ±50 ml, whichever is greater
  • MVV: ±10% of indication or ±15 L/min, whichever is greater
Precision (BTPS)Flow: PEF: ±5% of indication or 150 ml/sec, whichever is greater
Volume: FVC and FEV1: ±3% or 50 ml, whichever is greater
Minimum Tracing SizeFlow Volume: Flow (vertical): 5 mm/L/S; Volume (horizontal): 10 mm/L
Volume Time: Volume (vertical): 10 mm/L; Time (horizontal): 20 mm/S
CalibrationATS 3-speed or standard calibration check
Predicted Normals
  • Adult FVC: Crapo (1981), Cherniack (1972), Morris (1971/73), Knudson (1983), Roberts (1991), ECCS/ERS/Quanjer (1993), NHANES III (1999), GLI (2012)
  • Pediatric FVC: Hsu (1979), Knudson (1983), Polgar (1971), Warwick (1977), NHANES III (1999), Zapletal (1987), Wang (1993), Quanjer (1995), GLI (2012)
  • Adult MVV: Cherniack (1972)
  • Pediatric MVV: Polgar (1971), Zapletal (1987)
InterpretationATS/ERS 2005, BTS-NICE 2004-2005, NLHEP 2000, Enright 1987
Report FormatPre-test overlay with full page graphs
Pre/Post test overlay with full page graphs
Parameters MeasuredFVC, FEV0.5, FEV1, FEV6, FEV1/FEV6, FEV3, FEV1/FVC, FEV3/FVC, PEFR, PEFT, FEF25%, FEF50%, FEF75%, FEF25-75%, FIVC, FIV0.5, FIV1, FIV3, FIV1/FIVC, FIV3/FIVC, PIFR, FIF50%, FIF 25-75%, FIF.2-1.2, FVC/FIVC, Extrapolated Volume (Ext. Vol. BEV), EOTV, FET, MVV, RR, MTV, SVC
Languages AvailableEnglish, Spanish, French, German, Italian, Portuguese

Storage Conditions Temperature-15 to 50° C (5 to 122° F)
Relative Humidity< 90% (non-condensing)
Storage Atmospheric Pressure700 to 1060 hPa
Operating Conditions Temperature15 to 40° C (59 to 104° F)
Relative Humidity10 to 90% (non-condensing)
Operating Atmospheric Pressure700-1060 hPa



Office Medic
ManufacturerVectraCor
Country of OriginUnited States
ApplicationSoftware
For Use WithFor VectraCor Universal SmartECG & Orbit Portable Spirometer
Language OptionsEnglish, French, German, Italian, Portuguese, and Spanish.
Customizable Report Formats TypePDF, JPEG, and TIFF
ECG Indications for UseReceipt, Storage, Viewing, Printing and Interpretive Analysis of 12 channel simultaneous ECGs

  • Patient Population: Adult Male/Female
  • Environment of Use: Hospital, Clinical, and Home Use
Spirometry Indications for UseDiagnostic Spirometry

  • Patient Population: Male/Femail, Pediatric to Adult
  • Device Functionality: Diagnostic Spirometry
  • Spirometric Parameters: FVC, MVV, SVC, and FEF
  • Environment of Use: Hospital, Clinical, and Home use
WarrantyUp to 5 Years

Operating SystemWindows® 10, Windows® 11
Free Disk Space1 GB
RAM1 GB (min)
InternetInternet Explorer 9.0 (min)
Processor1.4GHZ (min) 2GHZ or faster recommended
InterfaceAn Available USB Port

Single Lead ReportPrints a single strip or averaged complex with scale options: 1x, 2x, 4x, 8x, 16x.
3×4 SimultaneousPrints 2.5-second segments of all twelve channels displayed at the same point in time along with a 10-second single channel rhythm strip.
3×4 SequentialPrints 2.5-second segments of all twelve channels displayed at the same point in time progressing in four sequential columns along with a 10-second single channel rhythm strip.
Average ComplexesPrint an average QRS complex for all 12 channels along with a 10-second single-channel rhythm strip.
6×1 Format (2 Page)Prints a 10-second trace of each channel.
6×2 Format (1 Page)Prints a 5-second trace of each channel.
Measurements TablePrints a chart with amplitude, slope, and duration data for all 12 channels.
IncludeAllows users to select whether to include Measurements, Interpretation, and/or Comments in the report(s).
Speed & SensitivityAllows users to select the Speed (12.5, 25, or 50 mm/s) and Sensitivity (5, 10, or 20 mm/mV) of the ECG reports.
Minor GridThis allows you to select the minor grid: Lines, Dots, or None.

Full Page GraphsTwo additional pages contain full-page F(V) and V(T) graphs in the report.
Overlay TestsOverlay the best three pre-tests and post-tests in Color or Black & White.
Custom Report HeaderCreate a custom header to reflect the physician, clinic, or any preferred details.
FVC ReportsPrints the F(V) and/or V(T) graphs at the bottom of the report.
Optional ParametersChoose the parameters you want to be displayed on the report.


×
Configurations

Currently Unavailable

×
Package Contents
  • Orbit™ Portable Spirometer
  • Pressure Tubes – 2
  • QRS Nose Clips – 5
  • QRS Pre-Calibrated Mouthpieces – 2
  • Office Medic™ software
×
Accessories and Parts
Part NumberItem Description
723000-00Volume Calibration Syringe
724050-00Nose-Clips
724100VB Filter for Orbit™ Spirometer
Z-5000-2608Pre-Calibrated Mouthpieces
Z-7000-2032Pressure Tubes

×
Reimbursements Information

This product maybe reimbursable, depending on various factors including current law and policies. Rally Inc. does not handle these reimbursements; instead, each reimbursement is handled solely between you, the customer, and the manufacturer, VectraCor, Inc.. Rally Inc. does not oversee these reimbursements. To check eligibility and get your reimbursements, please follow the manufacturer's reimbursements instructions.

You can find more reimbursements information for this product here.