Sensor Finger, Masimo LNCS Adhesive Sensor, Infant, Disposable for Connex IWS & VSM (20/CS) by Hillrom/Welch Allyn ID LNCS-INF-3

52-4-5685
      
Stock Est. Shipping Date: 29th April 2025

Sensor Finger, Masimo LNCS Adhesive Sensor, Infant, Disposable for Connex IWS & VSM (20/CS)
Sold by: EA OF 1

 Reviews
Better together

  • Total: $0.00

Rally #52-4-5685
Baxter / Hillrom / Welch Allyn #LNCS-INF-3
LNCS® Single-Patient-use Sensor (1/EA) (20/CS)

Sensor, Finger, SpO2, 3 ft cord, Body Weight: 3 - 20 kg, Infant , Single Patient Use, Latex-Free, Non-Sterile, Rx Only

Features
  • Disposable sensors prevent and reduct cross-contamination
  • Not made with natural rubber latex
  • SpO2 (pulse oximetry) sensor adheres comfortably to fingertip
  • Recommended for spot checks and continuous monitoring
The LNCS Single-Patient-use sensors are for continuous noninvasive monitoring of SpO2 and pulse rate in adult, pediatric, infant, and neonatal patients in various settings. They are compatible with Masimo SET oximetry and Nellcor pulse oximeters, except for OxiMax enabled instruments. The sensors are intended for single patient use and can be used in hospitals, mobile units, and home environments.

Caution: Federal Law (U.S.A.) Restricts This Device To Sale By Or On The Order Of A Physician.

For the State of California:
Warning: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.

×
Rally #52-4-5685
Manufacturer #LNCS-INF-3
GTIN00732094079142
BrandMasimo®
ManufacturerBaxter / Hillrom / Welch Allyn / Masimo
Country of OriginUnknown
ApplicationSpO2 Sensor
Securing MethodWrap-Around
Target AreaFinger
UsageSingle Patient Use
UserInfant
Latex IndicatorNot Made With Natural Rubber Latex
Sterile/Non-SterileNon-Sterile
UNSPSC Code42181803
WarrantySix Month Warranty

SensorNeo, Neo-L, Neo-3
Body Weight< 3 kg or > 40 kg
Application SiteNeonatal: hand or foot
Adult: finger or toe
Saturation Accuracy, No MotionNeonatal: ± 3%, Adult: ± 2%
Saturation Accuracy, Motion± 3%
Pulse Rate Accuracy, No Motion± 3 bpm
Pulse Rate Accuracy, Motion± 5 bpm
Low Perfusion AccuracySpO2: Neonatal ± 3%, Adult ± 2%
Pulse ± 3 bpm

SensorNeo, Neo-L, Neo-3
Body Weight< 3 kg or > 40 kg
Application SiteNeonatal: hand or foot
Adult: finger or toe
Saturation Accuracy, No MotionNeonatal: ± 3%, Adult: ± 2%
Pulse Rate Accuracy, No Motion± 3 bpm


All Compatible Products (Welch Allyn):

  • Connex® Integrated Wall System
  • Connex® Vital Signs Monitor

×
Configurations
Part Number Description Body Weight
LNCS Adtx Adult SpO2 Sensor, 18 in. > 30 kg
LNCS Adtx-3 Adult SpO2 Sensor, 3 ft. > 30 kg
LNCS Pdtx Pediatric SpO2 Sensor, 18 in. 10-50 kg
LNCS Pdtx-3 Pediatric SpO2 Sensor, 3 ft 10-50 kg
LNCS Inf Infant SpO2 Sensor, 18 in.
Replaceable Wrap Available
3-20 kg
LNCS Inf-3 Infant SpO2 Sensor, 3 ft.
Replaceable Wrap Available
3-20 kg
LNCS Inf-L Infant SpO2 Sensor, 3 ft. 3-20 kg
LNCS Neo Neonatal SpO2 Sensor, 18 in.
Replaceable Wrap Available
< 3 kg or > 40 kg
LNCS Neo-3 Neonatal SpO2 Sensor, 3 ft.
Replaceable Wrap Available
< 3 kg or >40 kg
LNCS Neo-L Neonatal SpO2 Sensor, 3 ft. < 3 kg or > 40 kg
LNCS NeoPt SofTouch™ Neonatal SpO2 Sensor, 18 in.
Replaceable Wrap Available
< 1 kg
LNCS NeoPt-3 SofTouch™ Neonatal SpO2 Sensor, 3 ft.
Replaceable Wrap Available
< 1 kg
LNCS NeoPt-L Neonatal SpO2 Sensor, 3 ft. < 1 kg
LNCS NeoPt-500 SofTouch™ Neonatal SpO2 Sensor, 18 in.
Replaceable Wrap Available
1 kg
LNCS E1® Adult SpO2 Ear Sensor, 3 ft. > 30 kg
LNCS TFA-1™ Adult/Pediatric SpO2 Forehead Sensor, 3 ft > 10 kg
×
Accessories and Parts
Currently Unavailable

×
Currently Unavailable


Size: Infant
No recommended products at the moment.