Starter Kit, Includes: Fluorescent Immunoassay Sofia® 2 Analyzer [1] and Influenza A + B [1 Kit = 25 Tests] CLIA Waived (1/KT) by Quidel Corporation ID 20310

188-1-2310
      
Stock Est. Shipping Date: 28th April 2025

Starter Kit, Includes: Fluorescent Immunoassay Sofia® 2 Analyzer [1] and Influenza A + B [1 Kit = 25 Tests] CLIA Waived (1/KT)
Sold by: KT OF 1

 Reviews
Better together

  • Total: $0.00

Rally #188-1-2310
Quidel #20310
Sofia 2 Influenza A+B FIA Starter Kit (1/KT)

Promotional Startup Kit, Influenza A+B with Analyzer and Install Pack, Fluorescent Immunoassay, CLIA Waived.

Quidel Promotional Starter Kit Bundle

Bundle Offer Valid Through December 31, 2025


Sofia® 2 Fluorescent Immunoassay Analyzer Features
  • Delivers reliable and objective results
  • Advanced algorithm generates results in minutes
  • Intuitive touchscreen interface for workflow customization
  • Features WALK AWAY mode for automatic result reporting
  • READ NOW mode allows analysis of multiple tests efficiently
  • Automatically stores patient results for easy access
  • Integrated barcode scanner for user and patient info
  • Capability to export data and integrate with LIS
Sofia® Influenza A+B FIA Features
  • CLIA waived for nasal and nasopharyngeal swabs, nasal aspirate and wash
  • Single specimen may be used for both Sofia RSV and Sofia Influenza
  • Can be use with Sofia or Sofia 2 and is compatible with viral transport media
  • Fixed–volume pipette collects and dispenses correct amount of sample needed for testing
Sofia 2 is a sophisticated benchtop analyzer that uses advanced fluorescent technology for accurate and fast test results. It has a touchscreen interface for easy operation and can connect to the Virena System for data management. Results are generated in minutes and can be stored automatically. The device offers two operating modes: WALK AWAY for automatic results after incubation and READ NOW for quick analysis of multiple tests. It is compact and allows for external media export and LIS integration.

The Sofia Influenza A+B Fluorescent Immunoassay (FIA) detects influenza A and B viral antigens using advanced immunofluorescence–based lateral-flow technology. It is easy to use and allows testing for both influenza and RSV from a single sample. The test uses a fixed-volume pipette for accurate sample collection and allows for the differential detection of influenza A and influenza B antigens. The test is CLIA waived for direct nasal swab, nasopharyngeal swab, and nasopharyngeal aspirate/wash specimens and can be used with Sofia or Sofia 2 devices.

Important Notes:
  • Rx Only.
  • For professional in-vitro diagnostic use.
  • This item is non-returnable. Please verify your ordering information before making a purchase.
For the State of California:
Warning: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.

×
Rally #188-1-2310
Manufacturer #20310
BrandSofia® 2
ManufacturerQuidel
Country of OriginUnknown
ApplicationPromotional Bundle Kit
Analyzer TypeBenchtop
CLIA ClassificationCLIA Waived
Contents(1) Leased Analyzer, (1) Install Pack, (1) Influenza A+B Kits
Number of Tests25 Tests
Purchase Program TypePromotional Bundle
Readout TypeDigital and Printout
Sample TypeNasal Swab / Nasopharyngeal Swab / Nasal Wash / Nasal Aspirate
Test NameInfluenza A+B Test
Time to ResultsSofia 2: Positive result in as few as 3 minutes, negative result 15 minutes
Sofia: 15 minutes



Sofia® 2 Fluorescent Immunoassay Analyzer
Manufacturer #20299
BrandSofia® 2
ManufacturerQuidel
Country of OriginUnknown
Analyzer TypeBenchtop
ApplicationFluorescent Immunoassay Analyzer
CLIA ClassificationCLIA Waived (when used with bundled test kit)
Readout TypeDigital and Printout
Dimensions22 cm deep x 12 cm wide x 12 cm high
Weight2 lbs (1 kg)
Power Supply Input100-240 VAC
50/60 Hz
Self-Switching (U.S./International)
2.93 Amp maximum
Sofia 2 Input7.5V DC, 2.5A
Replaceable BatteryLiPo rechargeable battery
Display4-inch color LCD touchscreen
LAN InterfaceRJ45 connector
Patient Test Result Storage1,000 tests maximum
QC Results Storage200 results maximum
Calibration Results Storage200 results maximum
User Storage1000 users maximum

Operating Temperature15°C to 30°C / 59°F to 86°F
Operating Humidity20% to 85% RH non-condensing
Operating Altitude2000 m maximum
Shipping and Storage Temperature–20°C to 55°C
Shipping and Storage Humidity20% to 85% RH non-condensing



Sofia® Influenza A+B FIA Fluorescent Immunoassay
Rally #188-1-2028
Manufacturer #20218
BrandSofia® Influenza A+B FIA
ManufacturerQuidel
Country of OriginUnited States
ApplicationRespiratory Test Kit
CLIA Complexity
  • Waived for direct nasal swab, nasopharyngeal swab, and nasopharyngeal aspirate/wash specimens
  • Moderate for nasopharyngeal swab and nasopharyngeal aspirate/wash specimens eluted in transport media
For Use WithFor Sofia® or Sofia 2® Flourescent Immunoassay Analyzer
Number of Tests25 Tests
Reading TypeMachine Read
Sample TypeNasal Swab / Nasopharyngeal Swab / Nasal Wash / Nasal Aspirate Sample
SpecialtyImmunoassay
Test FormatCassette Format
Test Kit TypeRapid
Test NameInfluenza A + B
Test TypeFluorescence Immunoassay (FIA)
Time to ResultsSofia 2: Positive Result in as few as 3 minutes, Negative Result 15 minutes
Sofia: 15 minutes
ControlsPositive and Negative
Shelf life24 months from date of manufacture
Kit Storage ConditionRoom Temperature (15°C to 30°C / 59°F to 86°F)
Transport Media CompatibilityCopan Universal Transport Media, Hank’s Balanced Salt Solution, M4, M4–RT, M5, M6, Modified Liquid Stuarts, Saline, Starplex Multitrans

Sample Type Sensitivity Specificity
Nasal Swab A: 90%, B: 89% A: 95%, B: 96%
Nasopharyngeal Swab A: 97%, B: 90% A: 95%, B: 97%
Nasopharyngeal Aspirate/Wash A: 99%, B: 88% A: 96%, B: 96%

A - Influenza A
B - Influenza B

Refer to Package Insert for additional and more detailed performance claims.


×
Configurations
20299 Sofia 2 Analyzer
20218 Sofia® Influenza A+B FIA
20314 Sofia 2 Installation Pack

×
Sofia® 2 Fluorescent Immunoassay Analyzer:
  • Sofia 2 with Rechargeable Battery
  • Power Adapter (Meanwell P/N: GSM25B07-P1J or equivalent)
  • QuickStart Guide
  • Calibration Cassette
Sofia Influenza A+B Fluorescent Immunoassay (25-Test Kit):
  • Individually Packaged Test Cassettes (25): Mouse monoclonal anti-influenza A and anti-influenza B antibodies
  • Reagent Tubes (25): Lyophilized buffer with detergents and reducing agents
  • Reagent Solution (25): Ampoules with salt solution
  • Sterile Nasal Swabs (25)
  • Small, Clear 120 µL Fixed Volume Pipettes (25)
  • Large, Pink 250 µL Fixed Volume Pipettes (25)
  • Influenza A and Influenza B Positive Control Swab (1): Swab is coated with non-infectious recombinant influenza A and influenza B antigens
  • Negative Control Swab (1): Swab is coated with heat-inactivated, non-infectious Streptococcus C antigen
  • Package Insert (1)
  • Quick Reference Instructions (1)
  • QC Card (located on kit box)
  • Printer Paper (1)
×
Optional Ancillaries (Sofia 2 Analyzer)
  • Dymo LabelWriter 450 Printer (Part #1752264)
  • Dymo LabelWriter 4XL Printer (Part #1755120) for Firmware 1.13.4 or higher only
  • Dymo Vinyl Label Roll, 2 5/16” x 4” (Part #30256)
  • Replacement Battery
×
Sofia® 2 FIA Analyzer Documentation Links
General Information Technical Bulletins
Sofia® Influenza A+B FIA Test Kit Documentation Links
General Documentations Technical Bulletins
×
Reimbursements Information
This product maybe reimbursable, depending on various factors including current laws and policies. Rally Inc. does not handle these reimbursements; instead, each reimbursement is handled solely between you, the customer, and the manufacturer, Quidel. Rally Inc. does not oversee these reimbursements. To check eligibility and get your reimbursements, please follow the manufacturer's reimbursements instructions.

You can find more informations on reimbursement details here.


No recommended products at the moment.