Diagnostic Cardiology Suite ECG with Wireless Acquisition Module (1/EA) by Hillrom/Welch Allyn ID CC-RXX-WAXX

52-4-6565
      
Stock Est. Shipping Date: 25th April 2025

Diagnostic Cardiology Suite ECG with Wireless Acquisition Module (1/EA)
Sold by: EA OF 1

 Reviews
Better together

  • Total: $0.00

Rally #52-4-6565
Baxter / Hillrom / Welch Allyn #CC-RXX-WAXX
Diagnostic Cardiology Suite ECG (1/EA)

Connex Cardio PC based 12-Lead Multi-Channel Resting ECG - software, Connex Cardio WAM wireless acquisition module, AHA 10 wire, 12-lead lead set with banana plugs, CardioSens Ultra II resting tab electrodes (pouch of 100), Clear Choice adapter clips (set of 10), Connex Cardio UTK

Features
  • Launches ECG and spirometry applications directly from EMR.
  • Uses one PC-based ECG system for spirometry and ECG exams.
  • ECG analysis software streamlines workflow by capturing and saving ECGs in two clicks.
  • VERITAS ECG algorithm limits filtering.
  • Wireless Acquisition Module (WAM) captures ECGs wirelessly.
  • Reduces repeat ECGs by capturing best 10 seconds of data.
  • Complies with ACC, AHA, HRS recommendations for adult/pediatric patient ECGs.
  • Uses DICOM and HL7 communication.
  • Securely control user logins, assign user roles and access audit trails
The Welch Allyn Diagnostic Cardiology Suite ECG is designed for healthcare professionals to acquire, analyze, and interpret ECG data for patients of all ages. The VERITAS algorithm used in the device helps in generating accurate measurements and advisory statements for physician review. It is intended for use in medical clinics, physician offices, and hospitals, and is not meant for monitoring vital signs in mobile or high-risk medical settings. The system also includes features for patient data management and communication with electronic medical records systems. Additionally, it is capable of specific age and gender interpretation criteria and provides a second opinion through diagnostic statements on the ECG report.

CAUTION: Federal law restricts this device to sale by or on the order of a physician.

For the State of California:
Warning: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.

×
Rally #52-4-6565
Manufacturer #CC-RXX-WAXX
GTIN00817655022604
BrandConnex®
ManufacturerBaxter / Hillrom / Welch Allyn
Country of OriginUnknown
ApplicationSoftware Package
For Use WithFor use with ECG Machine
UNSPSC Code43232610
Instrument Type12-lead resting electrocardiograph
Input ChannelsSimultaneous acquisition of all 12 leads
Standard Leads AcquiredI, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
Frequency Response0.05 Hz - 300 Hz
Gain2.5, 5, 10, 20 mm/mV
FiltersAC filter: None, 50 Hz, 60 Hz
Low-pass filters: 40 Hz, 150 Hz, 300 Hz
Digital Sampling Rate40,000 samples/sec/channel used for pacemaker spike detection
1,000 samples/sec/channel used for recording and analysis
Report FormatsStandard or Cabrera; 3+1, 3+3, 6, 6+6, or 12 channel
Acquisition DeviceWireless Acquisition Module
Storage CapacityUnlimited with external archive

Diagnostic Cardiology Suite Software13 Months
Wireless and Wired Acquisition Modules1 Year
UTK1 Year
Lead Wires90 Days
Clips90 Days
Spirometer Hardware1 Year

Operating SystemsMicrosoft Windows 10 Professional and Enterprise (64-bit)
Microsoft Windows 11 Professional and Enterprise

Note: If installing ELI Link with Diagnostic Cardiology Suite system, requires 64-bit OS to operate both.
Compatible Viewing Resolutions1366×768, 1680×1050, 1920×1080, 1920×1200, 2736×1824
Font Scaling100%
ProcessorPerformance equivalent or better than an Intel Core i3
RAMMinimum 4 GB
Hard Drive CapacityMinimum 250 GB (If client: minimum 160 GB)
ArchiveNetwork or external USB drive
Software InstallationDVD
Network100 Mbps connection or better
USB PortsRequires at least two USB 2.0 ports (WAM/AM12 modules, external USB drive)
Input DevicesStandard keyboard, mouse, ECG acquisition input device (e.g. WAM, AM12 modules)
Printing DeviceHP M501dn Windows Printer with HPUPD PCL5 driver or equivalent

Instrument TypePerformance equivalent to an Intel® Xeon® class, quad-core with hyperthreading
Resolution1024 x 768 or better
RAMMinimum 4 GB
Operating SystemMicrosoft Server 2016, Microsoft Server 2019
System Disk100 GB for OS and product installation (RAID recommended for data redundancy)
Data Disks550 GB hard drive space available
HD controller with 128 MB read/write cache (RAID recommended for data redundancy)


Specification can be found in the User Manual P.68 here.



Specification can be found in the User Manual P.69 here.



×
Configurations
CC-RXX-WAXX Diagnostic Cardiology Suite ECG with Wireless Acquisition Module
CC-RXX-AAXX Diagnostic Cardiology Suite ECG with AM12 Wired Acquisition Module
CC-RXX-WADX Diagnostic Cardiology Suite ECG with Wireless Acquisition Module and DICOM Connectivity
CC-RXX-AADX Diagnostic Cardiology Suite ECG with AM12 Wired Acquisition Module and DICOM Connectivity

×
Accessories and Parts
410370Spirometry Pressure Tube and Handle
7034803-Liter Spirometry Calibration Syringe
715006ECG Multifunction Electrode Adapter Clips, Set of 10.
720705Flow Transducers, Disposable, 25-Pack
720706Flow Transducers, Disposable, 100-Pack
9293-046-6010 wire AHA lead set with banana plugs for the WAM or AM12, gray
9293-046-64Replacement lead set, AHA, V1-V3 with banana plugs for the WAM or AM12, gray

Note: Additional accessory information can be found in the user manual (P.69) here.
×
SmartCare Service Program

Program Products Part Number Program Terms
Protection DCS-ECG S1-DCS-ECG-PRO-PS 3 Years
Protection DCS-Spirometry S1-DCS-SP-PRO-PS 3 Years

No recommended products at the moment.