Universal SmartECG (1/EA)
ECG System, Resting, 12 Channel, with Office Medic software, Electrodes and Adapters Included, Hub 85 x 91 x 20 mm, Leads Length: Limb 1m, Chest .6m.
[Combo Package Bundle Available: 790009-01 - ECG & Spirometer Combo, PC Based, Office Medic Software Included]
Universal SmartECG Features
- Store and analyze up to 12-channels of high-resolution ECG data.
- Electrodes and electrode adapters included.
- Office Medic software included for ease of use.
- Draws its power from the PC; No batteries required.
- Instantly stores the test data in its central database allowing you to manage & review it from anywhere.
- Create customizable reports in PDF, JPEG, and TIFF formats to integrate with your EMR.
- Multiple Language Options: English, French, German, Italian, Portuguese, and Spanish.
- Up to 5 years of Warranty
Office Medic is user-friendly software that comes with all VectraCor QRS ECGs and Spirometers. It allows users to collect, store, and review diagnostic data using a regular laptop, desktop, or tablet. The software saves test data in a central database, enabling access from anywhere and creating customizable reports in PDF, JPEG, and TIFF formats to integrate with EMR systems.
Note
- Rx Only - Federal law restricts this device to the sale by or on the order of a physician.
- This item is non-returnable and non-refundable. Please make sure it is the right product and quantity before you order.
Warning: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.
×
Universal Smart ECG
Office Medic
Rally # | 131-1-7050 |
Manufacturer # | Z-7000-0500 |
Brand | QRS® Universal ECG™ |
Manufacturer | QRS Diagnostic |
Country of Origin | United States |
Application | Electrocardiograph |
Type | Resting |
Display Type | Without Display |
Patient Leads | 12 Lead Cable |
Power Source | USB Connection |
UNSPSC Code | 4218170 |
Warranty | 3 Years |
Universal Smart ECG
Hub Weight | 280 - 335 grams (0.62 – 0.66 lb) |
Hub Dimensions | 85mm x 91mm x 20mm (3.3” x 3.6” x 0.8”) |
Patient Leads Length | 1.0 meter (3.3 ft) for limb leads 0.6 meter (2.0 ft) for chest leads |
PC Connection Length | 1.8 meter (5.9 ft) USB cable |
Patient Leads | 12 Lead Cable (10 patient leads) |
Case Material | ABS Plastic |
Electrode Connections | 4 mm Banana plug with "tab" or "snap" connectors |
Electrode Labeling | Abbreviations and colors to comply with either IEC or AAMI (AHA) standards |
Display and Operating Console | Dependent on PC (supplied by user) |
Gain/Sensitivity | 5, 10, 20 mm/mV |
Input Range | ±5 mV |
Acquisition sample rate | 1000 samples per second (compressed to 500Hz with peak picking and averaging algorithm) |
Heart Rate Range | 30 bpm - 200 bpm |
Frequency Response | 0.05 to 175Hz ± 3dB |
Defibrillator Protection | Patient leads are isolated from system and operator, with 5 kV protection |
Common Mode Rejection | -60dB (minimum) |
Safety Standards | Complies with IEC 60601-1, IEC 60601-1-2, and IEC 60601-2-25 |
Accuracy | Accurate to IEC 60601-2-25 essential performance requirements. |
Leads Off Indicators | Connection status for each lead is shown on Acquisitionscreen |
Power Source | Powered by PC via USB interface |
Supply Voltage | 5V DC |
Supply Current | <17mA DC |
Permanent Filters | High Pass: 0.05Hz 2nd order Low Pass: 175Hz 2nd order Baseline Wander: Baseline reset by adaptive zeroing algorithm |
Notch filter (Mains Noise Rejection) | 50Hz 4th order Butterworth 60Hz 4th order Butterworth |
Low pass (Muscle Artifact Filter) | 35Hz 4th order |
Report Capabilities | User selectable Report formats |
Operating Temperature | 10 to 35° C (50 to 95° F) |
Storage Temperature | -20 to 70° C (-4 to 158° F) |
Operating Relative Humidity | 20 to 85% (non-condensing) |
Storage Relative Humidity | 10 to 85% (non-condensing) |
Atmospheric Pressure | 70 kPA – 106 kPa |
Office Medic
Manufacturer | VectraCor |
Country of Origin | United States |
Application | Software |
For Use With | For VectraCor Universal SmartECG & Orbit Portable Spirometer |
Language Options | English, French, German, Italian, Portuguese, and Spanish. |
Customizable Report Formats Type | PDF, JPEG, and TIFF |
ECG Indications for Use | Receipt, Storage, Viewing, Printing and Interpretive Analysis of 12 channel simultaneous ECGs
|
Spirometry Indications for Use | Diagnostic Spirometry
|
Warranty | Up to 5 Years |
Operating System | Windows® 10, Windows® 11 |
Free Disk Space | 1 GB |
RAM | 1 GB (min) |
Internet | Internet Explorer 9.0 (min) |
Processor | 1.4GHZ (min) 2GHZ or faster recommended |
Interface | An Available USB Port |
Single Lead Report | Prints a single strip or averaged complex with scale options: 1x, 2x, 4x, 8x, 16x. |
3×4 Simultaneous | Prints 2.5-second segments of all twelve channels displayed at the same point in time along with a 10-second single channel rhythm strip. |
3×4 Sequential | Prints 2.5-second segments of all twelve channels displayed at the same point in time progressing in four sequential columns along with a 10-second single channel rhythm strip. |
Average Complexes | Print an average QRS complex for all 12 channels along with a 10-second single-channel rhythm strip. |
6×1 Format (2 Page) | Prints a 10-second trace of each channel. |
6×2 Format (1 Page) | Prints a 5-second trace of each channel. |
Measurements Table | Prints a chart with amplitude, slope, and duration data for all 12 channels. |
Include | Allows users to select whether to include Measurements, Interpretation, and/or Comments in the report(s). |
Speed & Sensitivity | Allows users to select the Speed (12.5, 25, or 50 mm/s) and Sensitivity (5, 10, or 20 mm/mV) of the ECG reports. |
Minor Grid | This allows you to select the minor grid: Lines, Dots, or None. |
Full Page Graphs | Two additional pages contain full-page F(V) and V(T) graphs in the report. |
Overlay Tests | Overlay the best three pre-tests and post-tests in Color or Black & White. |
Custom Report Header | Create a custom header to reflect the physician, clinic, or any preferred details. |
FVC Reports | Prints the F(V) and/or V(T) graphs at the bottom of the report. |
Optional Parameters | Choose the parameters you want to be displayed on the report. |
×
Configurations
Currently Not Available
Configurations
Currently Not Available
×
Package Contents
Package Contents
- Universal SmartECG 12-Channel ECG
- QRS Resting ECG Tab Electrodes – 100
- Sure-Lock Snap & Tab Electrode Adapters – 10
- Lead Placement Guide
- Office Medic or VectraplexECG software
×
Accessories and Parts
Accessories and Parts
Part Number | Item Description |
Z-5000-1920 | Resting ECG Tab Electrodes, Box of 4000 |
Z-5000-1919 | Resting ECG Tab Electrodes, Box of 1000 |
5000-1917 | Sure-Lock Snap and Tab Electrode Adapters |
V100300 | Wet Gel Monitoring Electrodes |
×
Documentation Links
Universal ECG
Documentation Links
Universal ECG
- Universal SmartECG Brochure
- ECG Analysis for Resting 12-lead ECG Physician’s Guide (12/2020) Rev D
- Universal ECG How-To Guide
- ECG Sample Report
- Hardware Warranty
- Universal ECG Leads Off Indication
- Office Medic User’s Manual (English) – Rev. L
- How to Download Office Medic Software on Windows 10/11 OS
- Office Medic Download Guide
- 3-year Limited Warranty/Software & License Agreement
- Optional Extended Warranty
- Database Conversion Instructions TN 02.09
- Backing-up and Restoring 6.x Office Medic Database
- Creating PDF, JPEG & TIFF Files in Office Medic
×
Video Links
Video Links
×
Reimbursements Information
This product maybe reimbursable, depending on various factors including current law and policies. Rally Inc. does not handle these reimbursements; instead, each reimbursement is handled solely between you, the customer, and the manufacturer, VectraCor, Inc.. Rally Inc. does not oversee these reimbursements. To check eligibility and get your reimbursements, please follow the manufacturer's reimbursements instructions.
You can find more reimbursements information for this product here.
Reimbursements Information
This product maybe reimbursable, depending on various factors including current law and policies. Rally Inc. does not handle these reimbursements; instead, each reimbursement is handled solely between you, the customer, and the manufacturer, VectraCor, Inc.. Rally Inc. does not oversee these reimbursements. To check eligibility and get your reimbursements, please follow the manufacturer's reimbursements instructions.
You can find more reimbursements information for this product here.