Rally #52-4-1552
Baxter / Hillrom / Welch Allyn #CP150AS-1ENB
CP 150 Resting Electrocardiograph with Spirometry (1/EA)
Welch Allyn CP 150 12-Lead Resting Electrocardiograph with Spirometry, Automatic ECG Interpretation, AHA ECG Cable with Disposable Electrodes, CardioPerfect Workstation Connectivity via USB and Ethernet, Color Touchscreen Display, 100-Test Memory; 3-Liter Calibration Syringe, 110-240 V, 50/60 Hz AC, IEC Plug Type-B.
Features
- Intuitive touchscreen display for more accuracy.
- Simplified EMR connectivity without a complicated interface.
- Portable and Battery Operated.
- Instant-On Feature helps eliminate typical start-up delays.
- Provides preview options for three-, six- or 12-lead ECGs.
- ECG print previews prior to printing help save time and reduce paper costs.
CAUTION: Federal law restricts this device to sale by or on the order of a licensed physician.
For the State of California:
Warning: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.
Warning: Product is considered HAZMAT and cannot ship via Air or to AK, GU, HI, PR, MP, VI.
Rally # | 52-4-1552 |
Manufacturer # | CP150AS-1ENB |
GTIN | 00732094185133 |
Brand | CP 150™ |
Manufacturer | Welch Allyn |
Country of Origin | Unknown |
Application | Electrocardiograph with Spirometry |
Display Type | Touch Screen Display |
Power Source | AC Power / Battery Operated |
Print Size | 8.5 X 11 Inch |
Display Size | 7 Inch Screen |
Type | Resting |
UNSPSC Code | 42181701 |
Warranty | Three Year Warranty |
Dimensions, incl. rubber feet (L x H x W) | 380.9 mm (15 in) x 358.1 mm (14.1 in) x 136.2 mm (5.4 in) |
Weight, incl. battery | 5.3 kg (11.7 lb) |
Keyboard type (power button) | Polyester overlay |
Display Type | TFT, 18 cm (7 in) color touchscreen |
Display Resolution | WVGA, 800 x 480 |
Instant On | Yes |
Gain settings | Auto ECGs: 2.5, 5, 10 or 20 mm/mV, Auto Rhythm ECGs: 10, 25 or 50 mm/mV |
Lead configurations | Standard, Cabrera |
Interpretation algorithm | MEANS (Modular ECG Analysis System) |
Common mode rejection ratio (CMRR) | >80 dB |
Input impedance | >2.5 MΩ |
Patient leakage | <10 μA (normal condition), <50 μA (single fault condition) |
Dynamic range | AC differential +/-5 mV, DC offset +/-300 mV |
Resolution | 2.5 μV |
A/D conversion | 16 bits |
Heart rate range | 30 to 250 bpm |
ECG storage (in test directory) | At least 100 ECG tests |
Frequency range | 0.3 to 150 Hz |
Digital sampling rate | 8000 samples/second/channel for data acquisition 500/1000 samples/second/channel for adult/pediatric ECG data analysis and storage |
Pacemaker detection | ANSI/AAMI EC11 |
Lead detection | Lead off and noise |
Power requirement | Universal AC power supply ~110–240 V, ~50/60 Hz, 1.5 A maximum |
AC fuses | Time-lag type, 2.0-amp 250-V rating, Littlefuse 0218002P or equivalent |
Protection against electric shock | Class I, internally powered type CF |
Rechargeable battery | 10.8 V, 6.75 Ah (73 Wh), 9-cells Lithium-Ion. Recharge time to 90% capacity: 4 hrs Full charge capacity—25 ECG tests @ 20 minutes/test. 8 hours of continuous operation or 250 continuous ECGs |
Filters | High-performance baseline 0.5 Hz Muscle tremor 35 Hz AC interference 50 Hz or 60 Hz |
Standard connectivity | 1 USB client, 4 USB hosts and Ethernet |
Connectivity options |
|
Electrodes | Rigorously tested for conductivity, adhesion and hypoallergenic qualities; exceed all AAMI standards |
Power cable | Meets or exceeds Type SJT |
Patient cable and leads | Meets or exceeds ANSI/AAMI EC53, EN/IEC 60601-2-25 and EN/IEC 60601-2-51 |
Mode of operation | Continuous |
Warranty | CP 150 device: 3 years. Patient cable/battery: 90 days. |
Thermal paper | Z-fold 21 cm (8.25 in) x 28 cm (11 in) x 200 sheets |
Thermal printer (internal) | Computer-controlled dot array, 8 dots/mm |
Thermal chart paper speeds | 10, 25 or 50 mm |
Report formats, internal printer | Auto: 3x4-2.5s @ 25 mm, 3x4-2.5s @ 50 mm, 3x4+1R-2.5s @ 25 mm 3x4+3R-2.5s @ 25 mm, 3x4-5.0s @ 25 mm, 3x4-5.0s @ 50 mm 6x2-5.0s @ 25 mm, 6x2-5.0s @ 50 mm,12x1-10.0s @ 25 mm Average cycles: 3x4+3R @ 25 mm, 3x4+3R @ 50 mm, 6x2+1R @ 25 mm, 6x2+1R @ 50 mm, no print |
Integrated 802.11 a/b/g/n inside the device, no external dongle required | |
Standards | Wireless Equivalent Privacy (WEP), Wi-Fi® Protected Access (WPA), IEEE 802.11i (WPA2) |
Encryption | Wireless Equivalent Privacy (WEP, RC4 Algorithm), Temporal Key Integrity Protocol (TKIP, RC4 Algorithm), Advanced Encryption Standard (AES, Rijndael Algorithm) |
Encryption key provisioning | Static (40-bit and 128-bit lengths), Pre-Shared (PSK), Dynamic |
802.1X Extensible Authentication Protocol Types | EAP-FAST, EAP-TLS, EAP-TTLS, PEAP-GTC, PEAP-MSCHAPv2, PEAP-TLS, LEAP |
Operating Conditions | Temperature: 10° – 40° C (50° – 104° F) Relative humidity: 15 – 95% noncondensing (30 – 70% for printing) Atmospheric air-pressure limits: 700 – 1060 hPa (525 – 795 mmHg) |
Storage Conditions | Temperature: -20° – 50° C (-4° – 122° F) Relative humidity: 15 – 95% noncondensing Atmospheric air-pressure limits: 700 – 1060 hPa |
Please go to the Education and Documents sections or below for specifications on electrodes.
Configurations
CP150A-1ENB | CP 150 Interpretive Electrocardiograph |
CP150AS-1ENB | CP 150 Interpretive Electrocardiograph with Spirometry |
Accessories and Parts
105410 | Welch Allyn ECG Interpretation Upgrade |
45008-0000 | Electrodes, Resting Tab, 1000-Pack |
714730 | Electrode, Reusable Suction Cup, 6-Pack |
715006 | ECG Multifunction Electrode Adapter Clips, Set of 10. |
715992 | ECG Limb Clamps, Reusable, AHA, 4-Pack |
719653 | 39 in. ECG Cable, 10 Lead, AHA, Banana |
719654 | CP50/CP150 10-Lead Patient Cable, IEC, Banana |
721328 | CP50 and/or CP150 10-Lead,AHA,Banana (1.5M/59 inches) ECG Cable |
08265-0000 | ECG Utility Cart, CP 100/CP 200 |
105341 | Office Cart with Free-Wheeling Plastic Wheels (no arm & shelf) |
105342 | Hospital Cart with Durable Rubber Wheels & Brake, (no arm & shelf) |
105343 | Cable Arm and Shelf Option, for 105341 and 105342 Carts (Cart Sold Separately) |
105353 | ECG Chart Paper, 200 Sheets per Pad / 5 Pads per Case |
BATT99 | 11.1V (6000mA) 9-Cell Lithium-Ion Rechargeable Battery |
PWCD-B | 8 ft. Power Cord with IEC Device Connector Type C-13, Plug Type B, North America |
410370 | Spirometry Pressure Tube and Handle |
703480 | 3-Liter Spirometry Calibration Syringe |
720705 | Flow Transducers, Disposable, 25-Pack |
720706 | Flow Transducers, Disposable, 100-Pack |
105660 | Spirometry Upgrade Kit |
CP150-0007 | Battery Casing Assembly Service Kit |
CP150-0009 | Printer Paper Tray Assembly Service Kit |
CP150-0010 | Printer Top Housing Service Kit |
CP150-0011 | Print Head Service Kit |
CP150-0012 | Gear Train Assembly |
CP150-0013 | Printer Motor Assembly |
CP150-0014 | Door Sensor Service Kit |
CP150-0016 | 60W Power Supply Service Kit |
CP150-0018 | Battery Cover Assembly Kit |
Documentation Links
Assembly Guide/Video
- CP150 and CP250 Mobile Stand, Assembly Guide/Video
- Welch Allyn CP150 Cable Arm and Shelf Option for Office and Hospital Carts, Assembly Instructions
- Welch Allyn CP150 Office and Hospital Carts, Assembly Instructions
- CP 150 Electrocardiograph, Brochure
- Welch Allyn Resting Electrocardiograph (ECG) Solutions for Long-Term Care
- Improving Chronic Care Management
- CP150 2.00.03 Software Update Update
- Connex CSK 4.1.X Software, Installation Guide
- ECG Cart, Cable Arm and Shelf Option, Installation Guide, Multi-Language
- CP 150 12 Lead Electrocardiograph with Resting ECG, Software Version 2.10.XX, Quick Reference Guide
- CP 150 Spirometry Option, Quick Reference Guide
- Welch Allyn CP 150 12-Lead Resting Electrocardiograph, Startup Guide
- No Calibration Required Statement For CP150, Reference
- CP150 Resting Electrocardiograph Accessory List, Multi-Language
- CP 150 ECG Printout Example
- CP 150 Electrocardiograph, Specification Sheet
- DICOM Conformance Statement for CP 150
- CP150 Resting ECG SmartCare Service Program
- Welch Allyn ELI Cart for Outpatient Care
- Welch Allyn Resting Tab Electrodes
- Welch Allyn ECG Monitoring Electrodes
- Means ECG Physicians Manual, User Manual
- CP 150 12-Lead Resting Electrocardiograph, Software Version 1.00.XX, User Manual
- CP 150 12-Lead Resting Electrocardiograph, Software Version 2.00.XX, User Manual
- CP 150 12-Lead Resting Electrocardiograph, Software Version 2.10.XX, User Manual
- CP 150 Spirometry Option, Software Version 2.10.XX, User Manual
Video Links
Services
S1-CP150 | CP150, 1 Year Comprehensive Partnership Program Service Agreement |
S1-CP150-2 | CP150, 2 Year Comprehensive Partnership Program Service Agreement |
S1-CP150-5 | CP150, 5 Year Comprehensive Partnership Program Service Agreement |
S1-CP150S | CP150 Spirometry, 1 Year Comprehensive Partnership Program Service Agreement |
S1-CP150S-2 | CP150 Spirometry, 2 Year Comprehensive Partnership Program Service Agreement |
S1-CP150S-5 | CP150 Spirometry, 5 Year Comprehensive Partnership Program Service Agreement |
S2-CP150 | CP150, BIO-MED Partner Program, CP150 Repair |
S2-CP150-2 | CP150, BIO-MED Partner 2 Year Program, CP150 Repair |
S1-CP150-PRO-PS | CP150 SmartCare Protection, 3 Year, Point of Sale |
S1-CP150-SP-PRO-PS | CP150 Spirometry SmartCare Protection, 3 Year, Point of Sale |