Rally #137-11-1180
Midmark #M9-042
Ritter® M9 Tabletop Autoclave Steam 9 Inch Diameter X 15 Inch Depth Automatic Door
STERILIZER, INSTR RITTER M9 STEAM AUTOCLAVE 115V, MEDICAL (1/EA)
- - - BRAND NEW AND FREE SHIPPING!!! - - -
Features- Fully automatic sterilizer with automatic door.
- Simple to use and effective; Simply load it, set it and forget it.
- Steam–Flush Pressure Pulse Air Removal System ensures proper steam penetration
- LCD Display for easy view of indicators
- Self program controls enable you to create different cycle parameters to meet specific instrument processing needs
- Four pre-programmed and two programmable cycles
- Speed-Clean Chamber Cleaner (002-0396-00)
- Pouch Rack Kit (#002-2108-01)
- Two small trays
- Two large trays
- Power Cord
- Care / Operation Card
- Speed-Clean SDS Sheet.
The Ritter M9 packs all of the reliable sterilizing power you need into a compact unit perfect for areas with limited space. With our strong heritage of quality, value and reliability, you can’t go wrong with the Ritter M9.
The M9 is simple to use and effective. Select your cycle and the time is set for you. Press “Start” and the M9 fills with the correct amount of water. Once the sterilization process is complete, the door opens automatically.
Product Specifications
Rally # | 137-11-1180 |
Manufacturer # | M9-042 |
Brand | Ritter® M9 |
Manufacturer | Midmark |
Country of Origin | United States |
Application | Countertop Autoclave |
Condition | New |
Cassette Capacity | 2 Full |
Door Type | Automatic Door |
Sterilization Type | Steam |
Length (with plug) | 20.4" (51.8 cm) |
Width | 15.3" (38.9 cm) |
Height (with printer) | 15.8" (40.1 cm) |
Minimum Countertop Area | 15.3" W x 17.9" D (38.9 x 45.4 cm) |
Chamber | 9" x 15" (22.9 x 38.1 cm) 3.5 gal usable volume (14.1 L) |
Trays | Two Large – 7.3" W x 12" L x 0.8" D (18.6 x 30.5 x 2.2 cm) Two Small – 5.6" W x 12" L x 0.8" D (14.3 x 30.5 x 2.2 cm) Pouch Rack: 5 slot |
Unit Weight | 73 lb (33.2 kg) |
Shipping Weight | 81 lb (36.7 kg) |
Water Reservoid Capacity | 1.1 gal (4.1 L) |
Electrical Rating: | 115 V models - 115 VAC (+/- 10%), 12 Amp, 50/60 Hz 230 V models - 230 VAC (+/- 10%), 6.4 Amp, 50/60 Hz |
Fuse Ratings: 115 VAC | F1 0.25 Amp, 250 V, Slo-blo, 1/4” x 1 1/4” F2 15 Amp, 250 V, Fast Acting, 1/4” x 1 1/4” |
Fuse Ratings: 230 VAC | F1 0.125 Amp, 250 V, Slo-blo, 5 x 20 mm F2 8 Amp, 250 V, Fast Acting, 5 x 20 mm |
Heat Emission | 5000 BTU / hr during operation |
Operating | 27-31 PSI (186-215 kPag) |
Max. Pressure at Door Release | 0.7 PSIg (5 kPag) |
Max. Pressure [Safety Valve Opens] | 40 PSIg (276 kPag) |
UNSPSC Code | 42281508 |
Standard Cycle Parameters
Pre-Programmed Cycle | Sterilization Temperature | Hot Cycle Time (Fill, Heat-Up + Vent in minutes) | Sterilization Time (in minutes) | Dry Time (in minutes) | Total Hot Cycle Time w/o Dry (in minutes) | Total Hot Cycle Time w/ Dry (in minutes) | |||||
All Units | M11 | M9 | M11 | M9 | M11 | M9 | M11 | M9 | M11 | M9 | |
Unwrapped | 270°F (132°C) | 19 | 11 | 3 | 3 | 30 | 30 | 22 | 14 | 52 | 44 |
Pouches | 270°F (132°C) | 20 | 12 | 4 | 4 | 30 | 30 | 24 | 16 | 54 | 46 |
Packs/Low Temp | 250°F (121°C) | 18 | 10 | 30 | 30 | 30 | 30 | 48 | 40 | 78 | 70 |
Handpieces | 270°F (132°C) | 26 | 15 | 4 | 4 | 30 | 30 | 30 | 19 | 60 | 49 |
Accessories, Tools and Service Parts
Accessories | Order Number |
Speed-Clean, 1 (16oz. [.47 liter]) bottle | 002-0396-00 |
Speed-Clean, 1 case (12 - 16oz. [.47 liter]) bottles | 002-0396-05 |
Thermal Printer | 9A599001 |
Data Logger | 9A682001 |
Printer Thermal Paper Roll (Refill) | 060-0016-00 |
Printer Stick-able Thermal Paper (Refill) | 060-0016-01 |
Door and Dam Gasket Kit (M9 / M9D only) | 002-0361-01 |
Pouch Rack Kit (M9 / M9D only) | 002-2108-01 |
Tray/Cassette Tool | 9A307001 |
Water Purity Specification Chart | ||
---|---|---|
AAMI ST-46 (ref.) | ||
Evaporate Residue | ≤ 15 mg/l | ≤ 15 ppm |
Silica | ≤ 2 mg/l | ≤ 2 ppm |
Iron | ≤ 0.2 mg/l | ≤ 0.2 ppm |
Cadmium | ≤ 0.005 mg/l | ≤ 0.005 ppm |
Lead | ≤ 0.05 mg/l | ≤ 0.05 ppm |
Rest of heavy metals, excluding Iron, Cadmium, and Lead 1 | ≤ 0.1 mg/l | ≤ 0.1 ppm |
Chloride | ≤ 3 mg/l | ≤ 3 ppm |
Phosphate | ≤ 0.5 mg/l | ≤ 0.5 ppm |
Conductivity (at 20°C) 2 | ≤ 50 μs/cm | TDS ≤ 25 ppm |
pH | 6.5 to 8 | |
Appearance | Colorless, clean, without sediment | |
Hardness | ≤ 0.1 mmol/l (.585 gr/gal) | ≤ 10 ppm |
- Documentations -
Brochure and Guidebook Service Information
- Operation and Care Guide for M9 / M11 Sterilizer -040 thru -043
- Quick Reference Service Guide -040 thru -043
- Sterilizer and QuickClean Startup Procedures
- Sterilizer and QuickClean Shutdown Procedures
- Midmark Advisory Notice - Sterilizer Technology
- CDC Infection Control Guidelines
- Data Logger 9A682001 Replacement
- Data Logger 9A682001 Installation
- Data Logger 9A682001 User Guide
- External Condensing Tank 9A260
- Thermal Printer Installation 9A599001
- Printer 9A259
- Tray Cassette Tool 9A307
- How To Install A Ritter M9/M11 Autoclave
- How To Load A Ritter M9/M11 Autoclave
- How To Operate A Ritter M9/M11 Autoclave
- How To Program A Ritter M9/M11 Autoclave
- How To Clean And Care For Your Ritter M9/M11 Autoclave
- How To Perform Monthly Maintenance On A Ritter M9/M11 Autoclave
- How To Install A Printer On A Ritter M9/M11 Autoclave
- Ritter Data Logger Installation
- Ritter Data Logger Registration
- Theory Of Operation
- Diagnostics
- Ritter M9 + M11 Steam Sterilizer Thermal Printer